![Hypertherm XPR300 Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/hypertherm/xpr300/xpr300_instruction-manual_2193792043.webp)
Qualifications and Requirements
2
XPR300
Instruction Manual
809480
43
Table 7
– Gas quality, pressure, and flow requirements
* Water can be used as a shield fluid for XPR300 plasma power supplies that have a VWI or OptiMix gas
Shield water requirements (VWI and OptiMix)
on page 47 for the specifications and
requirements for water that is used for shield purposes.
** Air compressors must provide air that meets the requirements of ISO Standard 8573-1 Class 1.4.2 (no more
than 100 particles per cubic meter of air at a size of 0.1 – 0.5 microns in the largest dimension and 1 particle
per cubic meter of air at a size of 0.5 – 5.0 microns in the largest dimension). I
mportant:
Any air compressors
that provide air to the cutting system must extract oil prior to air delivery.
*** Nitrogen is required for all mild steel processes.
†
Air is required for H
2
mix processes.
Code conformity
All customer-supplied equipment must meet applicable national and local codes for supply
gas and supply gas plumbing. Contact a licensed plumber for more information about the
codes in your location.
Any installation, modification, or repair of supply gas equipment or plumbing systems must
be done by a licensed plumber.
Gas*
Quality
Pressure
Flow rate
O
2
(oxygen)
99.5% pure, clean, dry,
oil-free**
7.5 bar ± 0.4 bar
(110 psi ± 5 psi)
71 slpm
150 scfh
N
2
(nitrogen)***
99.99% pure, clean, dry,
oil-free
7.5 bar ± 0.4 bar
(110 psi ± 5 psi)
181 slpm
380 scfh
Air**
,†
Clean, dry, oil free
consistent with
8573-1:2010 Class 1.4.2
7.5 bar ± 0.4 bar
(110 psi ± 5 psi)
118 slpm
250 scfh
H
2
(hydrogen)
99.995% pure
7.5 bar ± 0.4 bar
(110 psi ± 5 psi)
50 slpm
105 scfh
Ar (argon)
99.99% pure; clean, dry,
oil-free
7.5 bar ± 0.4 bar
(110 psi ± 5 psi)
118 slpm
250 scfh
F5 (95% nitrogen, 5% hydrogen)
99.98% pure
7.5 bar ± 0.4 bar
(110 psi ± 5 psi)
40 slpm
85 scfh
Содержание XPR300
Страница 1: ...XPR300 Plasma Instruction Manual 809480 Revision 2 English ...
Страница 18: ...Contents 18 809480 Instruction Manual XPR300 ...
Страница 34: ...Specifications 1 34 809480 Instruction Manual XPR300 ...
Страница 66: ...Qualifications and Requirements 2 66 809480 Instruction Manual XPR300 ...
Страница 188: ...Connect for Communication 4 188 809480 Instruction Manual XPR300 ...
Страница 192: ...Coolant Installation 5 192 809480 Instruction Manual XPR300 ...
Страница 230: ...Operation 6 230 809480 Instruction Manual XPR300 ...
Страница 337: ...Parts List 9 XPR300 Instruction Manual 809480 337 ...
Страница 343: ...Parts List 9 XPR300 Instruction Manual 809480 343 ...
Страница 380: ...Wiring Diagrams 10 380 809480 Instruction Manual XPR300 ...
Страница 381: ...381 Overview Sheet 1 of 22 013403 013403 ...
Страница 382: ...382 Plasma power supply 1 Sheet 2 of 22 013403 ...
Страница 383: ...383 Plasma power supply 2 Sheet 3 of 22 013403 ...
Страница 384: ...384 Plasma power supply 3 Sheet 4 of 22 013403 ...
Страница 385: ...385 Plasma power supply 4 Sheet 5 of 22 013403 ...
Страница 386: ...386 Plasma power supply 5 Sheet 6 of 22 013403 ...
Страница 387: ...387 Plasma power supply 6 Sheet 7 of 22 013403 ...
Страница 388: ...388 Plasma power supply 7 Sheet 8 of 22 013403 ...
Страница 389: ...389 Gas connect console 1 Sheet 9 of 22 013403 ...
Страница 390: ...390 Gas connect console 2 Sheet 10 of 22 013403 ...
Страница 391: ...391 Torch connect console Sheet 11 of 22 013403 ...
Страница 392: ...392 Coolant system Sheet 12 of 22 013403 ...
Страница 393: ...393 Gas system 1 Sheet 13 of 22 013403 ...
Страница 394: ...394 Gas system 2 Sheet 14 of 22 013403 ...
Страница 395: ...395 Gas system 3 Sheet 15 of 22 013403 ...
Страница 402: ...402 Wireless subsystem block diagram Sheet 22 of 22 013403 ...