Recommended grounding and shielding
Introduction
This section describes practices for grounding and shielding to protect a plasma cutting system
against radio frequency interference (RFI) and electromagnetic interference (EMI) (also called
noise
). It also describes the DC power ground and the service ground. The diagram at the end of
this section shows these types of grounds in a plasma cutting system.
The grounding practices in this section have been used on many
installations with excellent results, and Hypertherm recommends that
these practices be a routine part of the installation process. The actual
methods used to implement these practices may vary from system to
system, but should remain as consistent as possible. However, due to the
variation in equipment and installations, these grounding practices may
not succeed in every case to eliminate RFI/EMI noise issues.
Types of grounding
Service ground
(also called safety ground or potential earth (PE) ground) is the grounding system
that applies to the incoming line voltage. It prevents a shock hazard to any personnel from any of the
equipment or the cutting table. It includes the service ground coming into the plasma system and
other systems, such as the CNC and the motor drives, as well as the supplemental ground rod
connected to the cutting table. In the plasma circuits, the ground is carried from the plasma system
chassis to the chassis of each separate console through the interconnecting cables.
DC power ground
(also called cutting current ground) is the grounding system that completes the
path of the cutting current from the torch back to the plasma system. It requires that the positive
lead from the plasma system be firmly connected to the cutting table ground bus with a properly
sized cable. It also requires that the slats, on which the workpiece rests, make firm contact with the
table and the workpiece.
RFI and EMI grounding and shielding
is the grounding system that limits the amount of electrical
noise emitted by the plasma and motor drive systems. It also limits the amount of noise that is
received by the CNC and other control and measurement circuits. The grounding practices
described in this section mainly target RFI and EMI grounding and shielding.
Содержание XPR300
Страница 1: ...XPR300 Plasma Instruction Manual 809480 Revision 2 English ...
Страница 18: ...Contents 18 809480 Instruction Manual XPR300 ...
Страница 34: ...Specifications 1 34 809480 Instruction Manual XPR300 ...
Страница 66: ...Qualifications and Requirements 2 66 809480 Instruction Manual XPR300 ...
Страница 188: ...Connect for Communication 4 188 809480 Instruction Manual XPR300 ...
Страница 192: ...Coolant Installation 5 192 809480 Instruction Manual XPR300 ...
Страница 230: ...Operation 6 230 809480 Instruction Manual XPR300 ...
Страница 337: ...Parts List 9 XPR300 Instruction Manual 809480 337 ...
Страница 343: ...Parts List 9 XPR300 Instruction Manual 809480 343 ...
Страница 380: ...Wiring Diagrams 10 380 809480 Instruction Manual XPR300 ...
Страница 381: ...381 Overview Sheet 1 of 22 013403 013403 ...
Страница 382: ...382 Plasma power supply 1 Sheet 2 of 22 013403 ...
Страница 383: ...383 Plasma power supply 2 Sheet 3 of 22 013403 ...
Страница 384: ...384 Plasma power supply 3 Sheet 4 of 22 013403 ...
Страница 385: ...385 Plasma power supply 4 Sheet 5 of 22 013403 ...
Страница 386: ...386 Plasma power supply 5 Sheet 6 of 22 013403 ...
Страница 387: ...387 Plasma power supply 6 Sheet 7 of 22 013403 ...
Страница 388: ...388 Plasma power supply 7 Sheet 8 of 22 013403 ...
Страница 389: ...389 Gas connect console 1 Sheet 9 of 22 013403 ...
Страница 390: ...390 Gas connect console 2 Sheet 10 of 22 013403 ...
Страница 391: ...391 Torch connect console Sheet 11 of 22 013403 ...
Страница 392: ...392 Coolant system Sheet 12 of 22 013403 ...
Страница 393: ...393 Gas system 1 Sheet 13 of 22 013403 ...
Страница 394: ...394 Gas system 2 Sheet 14 of 22 013403 ...
Страница 395: ...395 Gas system 3 Sheet 15 of 22 013403 ...
Страница 402: ...402 Wireless subsystem block diagram Sheet 22 of 22 013403 ...