Do System Tests to Identify Defective Components
5
96
810430
Troubleshooting Guide
Powermax65/85/105 SYNC
8.
Install the DSP PCB, but disconnect the ribbon cable from J6 on the DSP PCB. Measure the
voltage again from pin 4 to ground. Is the voltage correct now?
If yes, replace the control PCB.
If no, replace the DSP PCB.
9.
If all of the voltage measurements are correct but you continue to see the same fault code,
replace the power PCB.