Access Service Information and Settings
6
138
810430
Troubleshooting Guide
Powermax65/85/105 SYNC
Plasma power supply performance and operation data
Go to the Power Supply Data screen (
POWER SUPPLY DATA
) to see information about plasma
power supply performance and use.
1.
Select
on the main menu screen.
2.
Select
to go to the
POWER SUPPLY DATA
screen.
I –
This field shows the set current followed by the live output current (in amperage). You can use
the first part of this field to adjust the set current if necessary for troubleshooting.
P –
This field shows the inlet set pressure followed by the actual output gas pressure (in psi).
When the system in manual mode, you can use the first part of this field to adjust the set
pressure if necessary for troubleshooting.
The system cannot go into manual mode from this screen.
F –
This field shows the active fault code (if any).
VL –
This field shows the input voltage.
VB –
This field shows the bus voltage (VBUS).
VO –
This field shows the arc voltage.
IP –
This field shows the boost PFC IGBT current in amperage. This field shows on the screen for
CSA and for Powermax105 SYNC 230 V – 400 V CE models only.
Содержание Powermax105
Страница 1: ...Powermax65 85 105 SYNC Troubleshooting Guide 810430 REVISION 0 ENGLISH ...
Страница 12: ...Before You Begin 1 12 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Страница 132: ...Do System Tests to Identify Defective Components 5 132 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Страница 172: ...How the Plasma Power Supply Operates 7 172 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Страница 174: ...System Diagrams 8 174 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Страница 180: ...System Diagrams 8 180 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...