Do System Tests to Identify Defective Components
5
Powermax65/85/105 SYNC
Troubleshooting Guide
810430
105
Test 7 – Procedure for a machine torch
1.
Make sure that the torch is set to the green “ready to fire” (
) position.
2.
Look at the main screen as you set the power switch on
the plasma power supply to ON (
I
). Do you see the
“torch started” icon (
) and the 0-51-0 fault code?
If no, continue with
Examine the CNC and the machine interface cable
1.
Disconnect the machine interface cable from the rear of the plasma power supply. This is the
14-pin cable that connects the plasma power supply to the CNC. Refer to
2.
Do a quick restart. If the fault code goes away and the system operates correctly, reboot the
CNC. This can remove a start signal if there is one pending.
3.
Connect the machine interface cable to the plasma power supply, and do a quick restart again.
If you continue to see the 0-51-0 fault code, disconnect the machine interface cable from the
plasma power supply again.
4.
Do a check for continuity on pin 3 and on pin 4 in the machine interface cable connector. Refer
to
on page 106. Is there continuity on both pins?
If yes, there can be a problem with the CNC or with the cable. Continue with the next step.
If no, there can be a problem in the plasma power supply. Continue with
5.
Do a check for open circuits in the machine interface cable between pin 3 and the CNC and
pin 4 and the CNC. Are the signals open?
If yes, there can be a problem with the CNC. Continue with
If no, there can be a problem with the cable. Continue with the next step.
6.
Disconnect the machine interface cable from the CNC. Do a check for short-circuited wires in
the cable. If there is a wire that is short-circuited, replace the machine interface cable.
7.
If there is not a problem with the machine interface cable, contact a support technician for the
CNC to identify possible problems that can prevent the torch from firing.
Содержание Powermax105
Страница 1: ...Powermax65 85 105 SYNC Troubleshooting Guide 810430 REVISION 0 ENGLISH ...
Страница 12: ...Before You Begin 1 12 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Страница 132: ...Do System Tests to Identify Defective Components 5 132 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Страница 172: ...How the Plasma Power Supply Operates 7 172 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Страница 174: ...System Diagrams 8 174 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Страница 180: ...System Diagrams 8 180 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...