Troubleshooting for Fault Codes
3
Powermax65/85/105 SYNC
Troubleshooting Guide
810430
61
3-51-1
Yellow
Red
An inverter IGBT saturation
fault occurred. The inverter
current is too high.
The top and bottom inverter IGBTs are starting
in phase instead of 180° out of phase.
• Do a test of the 2 inverter IGBTs. Refer to
• Replace the module if either IGBT is
defective.
• If necessary, replace the power PCB.
3-52-0
A short circuit caused
high-current distortion in the
inverter IGBT. This is
sometimes referred to as a
shoot-through.
3-60-0
Yellow
Red
The DSP PCB does not
recognize the power PCB.
• Make sure that the correct power PCB is
installed for the plasma power supply.
3-70-0
Yellow
Red
There is an internal serial
communications fault
between the DSP PCB and
power PCB.
There is a fault with the communication between
the DSP PCB and the power PCB.
• Examine the cable that connects to both the
DSP PCB and the power PCB.
• If necessary, replace the DSP PCB or the
power PCB.
Fault
code
Fault
icon
Fault
LEDs
Description
Solutions
Содержание Powermax105
Страница 1: ...Powermax65 85 105 SYNC Troubleshooting Guide 810430 REVISION 0 ENGLISH ...
Страница 12: ...Before You Begin 1 12 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Страница 132: ...Do System Tests to Identify Defective Components 5 132 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Страница 172: ...How the Plasma Power Supply Operates 7 172 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Страница 174: ...System Diagrams 8 174 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Страница 180: ...System Diagrams 8 180 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...