Troubleshooting for Fault Codes
3
40
810430
Troubleshooting Guide
Powermax65/85/105 SYNC
The status LED on the SmartSYNC hand torch also shows the fault status.
When the status LED on the hand torch is yellow, the LED can be flashing or solid, as follows:
The yellow status LED flashes quickly (multiple flashes per second) for fault codes that are
notices. Notices show the
or
fault icon. Refer to
The yellow status LED also flashes quickly for the 0-32-1 fault code to remind you that it is
necessary to install a new cartridge. The 0-32-1 fault code shows the
fault icon.
The yellow status LED flashes slowly (one flash every 1–2 seconds) for the 0-98-2 torch
communication fault code.
The yellow status LED also flashes slowly when the system is in basic mode. Refer to
The yellow status LED is solid (does not flash) for all other 0-
nn
-
n
fault codes.
Green
= prepared
to cut
Yellow
= a 0-
nn
-
n
fault code, or the
torch is locked
Red
= a 0-32-0,
1-
nn
-
n
, 2-
nn
-
n
, or
3-
nn
-
n
fault code
Содержание Powermax105
Страница 1: ...Powermax65 85 105 SYNC Troubleshooting Guide 810430 REVISION 0 ENGLISH ...
Страница 12: ...Before You Begin 1 12 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Страница 132: ...Do System Tests to Identify Defective Components 5 132 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Страница 172: ...How the Plasma Power Supply Operates 7 172 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Страница 174: ...System Diagrams 8 174 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Страница 180: ...System Diagrams 8 180 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...