Prepare to Troubleshoot Internal Components
2
Powermax65/85/105 SYNC
Troubleshooting Guide
810430
31
Table 4
— Powermax105 SYNC power switch resistance values
Figure 3
— Powermax105 SYNC
8.
If you do not find a problem during the internal inspection or the initial resistance check, and the
power supply still does not operate correctly, do the following:
Troubleshooting for Common Problems
on page 63. This section gives the causes
and solutions for many common troubleshooting conditions.
Refer to the system wiring diagrams on
Make sure that you understand the theory of operation before you do troubleshooting
procedures. Refer to
Before you purchase a major replacement component, make sure that you correctly identify
the problem and solution with Hypertherm Technical Service or the nearest Hypertherm
repair facility.
Measure resistance from
Power PCB location
All models with torch
disconnected
Work lead to nozzle
J27 to black wire
230 kΩ
Work lead to electrode
J27 to J28 (red wire)
9 kΩ
Electrode to nozzle
J28 (red wire) to black wire
230 kΩ
Output to ground
> 20 mΩ
RED
J27
WORK
LEAD
J26
J32
J28
Black wire
Red wire (J28)
Содержание Powermax105
Страница 1: ...Powermax65 85 105 SYNC Troubleshooting Guide 810430 REVISION 0 ENGLISH ...
Страница 12: ...Before You Begin 1 12 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Страница 132: ...Do System Tests to Identify Defective Components 5 132 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Страница 172: ...How the Plasma Power Supply Operates 7 172 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Страница 174: ...System Diagrams 8 174 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...