Troubleshooting for Fault Codes
3
Powermax65/85/105 SYNC
Troubleshooting Guide
810430
51
0-50-0
Yellow
Yellow
The cartridge is off, the torch
was disconnected, or the
torch was in the yellow
lock (
X
) position during a
restart.
This fault code stops the system from operating.
Do the following.
• This fault code shows when you do a restart
while the torch-lock switch is in the yellow
lock (
X
) position. Move the torch-lock
switch to the green “ready to fire” (
)
position to continue. Refer to fault code
0-50-1
below.
• This fault code also shows if the torch is
disconnected when you set the plasma
power supply to ON (
I
). Connect the torch
to the plasma power supply. Do a quick
restart.
• This fault code also shows when a cartridge
is not installed correctly. Remove the
Hypertherm cartridge and install it correctly.
•
Machine torch:
This fault code shows when
you remove the cartridge without first
setting the power switch to OFF (
O
) or
moving the torch-lock switch to the yellow
lock (
X
) position. Lock and unlock the torch,
or do a quick restart.
•
Mini machine torch:
This fault code can
show if you change the cartridge while the
power switch on the plasma power supply
is set to ON (
I
). Do a quick restart.
• If the Hypertherm cartridge is in good
condition and is installed correctly, the torch
has possible damage. If possible, do a test
with a different torch that is known to
operate correctly.
• Make sure that the
plunger in the torch
head moves freely.
Push down the
plunger and then
release. A plunger
in good condition
goes back to its
start position. If the
plunger no longer operates correctly,
replace the torch body.
Fault
code
Fault
icon
Fault
LEDs
Description
Solutions
Содержание Powermax105
Страница 1: ...Powermax65 85 105 SYNC Troubleshooting Guide 810430 REVISION 0 ENGLISH ...
Страница 12: ...Before You Begin 1 12 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Страница 132: ...Do System Tests to Identify Defective Components 5 132 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Страница 172: ...How the Plasma Power Supply Operates 7 172 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Страница 174: ...System Diagrams 8 174 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Страница 180: ...System Diagrams 8 180 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...