Troubleshooting for Fault Codes
3
Powermax65/85/105 SYNC
Troubleshooting Guide
810430
41
Identify fault icons
Notice –
This icon identifies faults that have a negative effect on cut quality or
performance but do not prevent the plasma power supply from continuing to
operate in most conditions. The 0-14-0 fault code shows this icon but will stop
the system from operating.
Fault –
This icon identifies faults that cause the plasma power supply to stop cutting.
Error –
This icon identifies faults for which repair or replacement of internal
components is necessary.
Torch Cap Sensor –
This icon identifies when the SmartSYNC torch is in the yellow
lock (
X
) position. It also identifies fault conditions in which the Hypertherm
cartridge is loose, incorrectly installed, or missing.
Temperature –
This icon identifies fault conditions in which the plasma power supply
is outside the range of permitted operating temperatures.
Gas –
This icon identifies fault conditions in which the gas supply is disconnected
from the plasma power supply or there is a problem with the gas supply.
Cartridge Not Recognized –
This icon shows when a cartridge cannot communicate
with the plasma power supply.
When a cartridge cannot communicate with the plasma power supply, the
plasma power supply cannot set operating parameters or record cartridge data.
Cartridge End-of-Life –
This icon shows when the cartridge is at end-of-life.
Hypertherm strongly recommends that you install a new cartridge when you get
this fault.
Internal Serial Communications Interface –
This icon identifies faults with serial
communications that occur between the LCD/control PCB and the DSP PCB.
Cartridge Communications –
This icon identifies faults with wireless
communications that occur between the Hypertherm cartridge and the
SmartSYNC torch.
Содержание Powermax105
Страница 1: ...Powermax65 85 105 SYNC Troubleshooting Guide 810430 REVISION 0 ENGLISH ...
Страница 12: ...Before You Begin 1 12 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Страница 132: ...Do System Tests to Identify Defective Components 5 132 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Страница 172: ...How the Plasma Power Supply Operates 7 172 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Страница 174: ...System Diagrams 8 174 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Страница 180: ...System Diagrams 8 180 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...