Do System Tests to Identify Defective Components
5
108
810430
Troubleshooting Guide
Powermax65/85/105 SYNC
Test 8 – Torch cap switch
If a new Hypertherm cartridge does not cause the 0-50-0 fault to go away, there can be a problem
with the torch or with the plasma power supply.
Examine the torch and torch lead
1.
Disconnect the torch from the plasma power supply.
2.
Make sure that a cartridge is correctly installed on the torch.
The cartridge must not be too loose or too tight.
3.
Make sure that the torch is set to the green “ready to fire” (
)
position.
4.
Measure the resistance between pin 5 and pin 7 in the torch
connector. Refer to
on page 109. Is the resistance
very low?
If yes, continue with the next step.
If no, the cap-sensor switch in the torch is open. Continue
with
5.
Set the torch to the yellow lock (
X
) position.
6.
Measure the resistance between pin 5 and pin 7 in the torch
connector again. Is the resistance open?
Examine the plasma power supply
If no, the cap-sensor switch circuit is closed. Continue with
the next step.
Содержание Powermax105
Страница 1: ...Powermax65 85 105 SYNC Troubleshooting Guide 810430 REVISION 0 ENGLISH ...
Страница 12: ...Before You Begin 1 12 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Страница 132: ...Do System Tests to Identify Defective Components 5 132 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Страница 172: ...How the Plasma Power Supply Operates 7 172 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Страница 174: ...System Diagrams 8 174 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...
Страница 180: ...System Diagrams 8 180 810430 Troubleshooting Guide Powermax65 85 105 SYNC ...