Access Service Information and Settings
6
Powermax65/85/105 SYNC
Troubleshooting Guide
810430
139
TP –
This field shows the boost PFC IGBT temperature in Celsius. This field shows on the screen
for CSA and for Powermax105 SYNC 230 V – 400 V CE models only.
TI –
This field shows the inverter IGBT temperature in Celsius.
STA –
This field shows the total number of torch starts the plasma power supply has done in its life.
XFR –
This field shows the total number of arc transfers the plasma power supply has done in its
life.
PT –
This field shows the cumulative pilot arc time in hours, minutes, and seconds (
HH:MM:SS
)
that the plasma power supply has had in its life.
XT –
This field shows the cumulative arc transfer time in hours, minutes, and
seconds (
HH:MM:SS
) that the plasma power supply has had in its life.