Functional levels pump control
Functional level “OPERATION”
Suited to select and adjust the pump operation modes (manual, contact, analogue).
Pump is dosing the set capacity (l/h or ml/h). Setting is
done via the operator wheel.
Pump is dosing the set volume (ml/contact). Setting is
done via the operator wheel.
Setting range 0.0013
– 12.8 ml/contact
The frequency of the incoming contacts is multiplied by
the set dosing volume. The pump is operated in constant
operation with maximum stroke frequency if the value
exceeds the maximum pump capacity. Excessive
contacts are ignored as long as the memory function is
not active.
Pump is dosing dependent on external analogue signal.
The dosing volume is proportional to the signal input
value in mA.
Setting is done via the operator wheel.
Operation
mode
Input value
Dosing
capacity
4
– 20 mA
≤ 4.1 mA
≥ 19.8 mA
0 %
100 %
0
– 20 mA
≤ 0.1 mA
≥ 19.8 mA
0 %
100 %
Function levels “INFO – ALARM – SETUP”
Any settings in that levels shall be done by our service staff or authorized experts only.
Storage of operator / user settings
The pump settings are stored automatically after 10 minutes and are kept after mains failure.
Содержание HydroDOS HD550G
Страница 19: ...I 19 103 Last change 04 2016 E P AL TW PW Subject to technical modifications 2 2 Installation schematics...
Страница 39: ...I 39 103 Last change 04 2016 E P AL TW PW Subject to technical modifications...
Страница 43: ...I 43 103 Last change 04 2016 E P AL TW PW Subject to technical modifications Calibration...
Страница 98: ...I 98 103 Last change 04 2016 E P AL TW PW Subject to technical modifications Technical documents...
Страница 102: ...I 102 103 Last change 04 2016 E P AL TW PW Subject to technical modifications 4 Installation drawing...