Model code
VMU 1 ATEX II 2G IIC T4
en(us)
Page 55 / 60
BEWA VMU _4_ATEX-II2GIICT4_4066057 en-us 2015-10-12.doc
2015-10-12
Model code
VMU - 1 - M - G - A - 1 - BM -
z / -S5D5-PKZ
Type
VMU = VarnishMitigation
Unit
Size
1
= 1x VarnishMitigation element
Flow rate
≈
2.2 l/min
4
= 4x VarnishMitigation element
Flow rate
≈
8.9 l/min
Mechanical type
M = mobile
S =
stationary
Pump version
G
= Gear pump with motor
z =
without
pump
Voltage, frequency, power supply
A
= 400 V, 50 Hz, 3 Ph
B
= 415 V, 50 Hz, 3 Ph
C
= 200 V, 50 Hz, 3 Ph
D
= 200 V, 50 Hz, 3 Ph
E
= 220 V, 60 Hz, 3 Ph
F
= 230 V, 60 Hz, 1 Ph
G
= 380 V, 60 Hz, 3 Ph
H
= 440 V, 60 Hz, 3 Ph
I
= 500 V, 50 Hz, 3 Ph
K
= 480 V, 60 Hz, 3 Ph
L
= 220 V, 50 Hz, 3 Ph
M
= 230 V, 50 Hz, 1 Ph
N
= 575 V, 60 Hz, 3 Ph
O
= 460 V, 60 Hz, 3 Ph
X
= Other voltages on request
z
= Without electro motor
Prefilter
1
= Pre-filter (OLF-5 top-loader)
z =
Without
pre-filter
Clogging indicator
BM
= Differential pressure indicator - optical (VM2BM.1)
for pre-filter and protective filter
C
= Differential pressure indicator – electric (VM2C.0)
for pre-filter
Differential pressure indicator – optical (VM2BM.1)
for protective filter
Supplementary details
AS =
AquaSensor
AS1000
The sensor is only connected hydraulically.
z =
without
Supplementary details
S5D5
= Suction / return hose with lance, length = 5 m
SKDK
= Suction / return hose with threaded connection, length = 5
m
PKZ
= On-off switch with motor protection switch
FA1
= On-off switch with switch-off when protective filter is clogged
(neutral wire required)
FA2
= On-off switch with switch-off when protective filter is clogged
(no neutral wire required)
ATEX =
ATEX
design
Содержание VarnishMitigation Unit
Страница 59: ......