Performing maintenance
VMU 1 ATEX II 2G IIC T4
en(us)
Page 38 / 60
BEWA VMU _4_ATEX-II2GIICT4_4066057 en-us 2015-10-12.doc
2015-10-12
Performing maintenance
The safety and availability of the unit depend on performing cyclical
maintenance.
DANGER
Spark formation during dismantling /
maintenance
Risk of explosion / Danger of fatal injury
►
Carry out maintenance work outside or when
there is no explosive air environment present.
►
Use only spark-free tools for the installation
of the VMU in explosion-hazard
environments.
WARNING
Hydraulic system is under pressure
Danger of bodily injury
►
The hydraulic system must be depressurized
before performing any work on it.
►
Switch the unit off at the main switch and
unplug the power connector.
►
Close all shut-off devices from and to the
power unit.
If defects which affect explosion protection are discovered during
check-ups or maintenance, then the unit is to be taken out of
service until the defect is remedied.
Repair and servicing work is not permitted on damaged pressure-
resistant sealed components (e.g. evacuation pump motor). In
this case, replace the installed component.