Switching unit on/off
VMU 1 ATEX II 2G IIC T4
en(us)
Page 37 / 60
BEWA VMU _4_ATEX-II2GIICT4_4066057 en-us 2015-10-12.doc
2015-10-12
Bleeding the ion exchange column
WARNING
Hot fluid
Risk of burns
►
Make sure that hot fluid can exit when
bleeding.
Bleed the ion exchange column through the air bleed screw (1) in the cover.
Do not unscrew the air bleed screw (1)
completely. It has ventilation slots.
If fluid leaks out, tighten the air bleed
screw (1) again.
Bleed the housing every time you change the element or on draining.
Bleeding the pre-filter and safety filter
To bleed, carefully open the air bleed
screw (Air Bleed) on the filter housing
cover.
If fluid leaks out, tighten the air bleed
screw (Air Bleed) again.