Switching unit on/off
VMU 1 ATEX II 2G IIC T4
en(us)
Page 36 / 60
BEWA VMU _4_ATEX-II2GIICT4_4066057 en-us 2015-10-12.doc
2015-10-12
Switching unit on/off
1- Pre-fill the power unit using the pump or
using the suction hose when the motor is off.
Without prefilling, the anti-dry running
protection will activate and it will not be
possible to switch on the power unit.
2- Switch the VMU on or off at the on/off
switch.
After switching on the motor, monitor the suction
action of the pump through the suction hose.
If the unit is not feeding medium after a maximum of
5 minutes of operation, switch it off.
Pre-fill the power unit using the pump or using the
suction hose when the motor is off.
Switch the unit on again and monitor the suction
action.
9
3
6
12
max. 5 min
During operation, always monitor the clogging indicator / differential pressure
gauge on the pre-filter and safety filter so as to know when to replace used
filter elements in good time.
Check the service life of the VME elements using cyclical lab analyses,
especially using MPC values and their trend behavior.
You can view the current operating pressure on the pressure gauge ion
exchange column. The maximum permissible pressure is 8 bar.