Performing maintenance
VMU 1 ATEX II 2G IIC T4
en(us)
Page 45 / 60
BEWA VMU _4_ATEX-II2GIICT4_4066057 en-us 2015-10-12.doc
2015-10-12
down to the electric motor.
3.
Remove the tensioning clamp on the filter
bowl cover by completely removing the
nut.
Remove the housing clamp.
4.
Carefully lift up the filter bowl cover to
remove it.
Turn it slightly clockwise. This ensures
that the filter element remains locked on
the cover.
Turn counterclockwise to detach
the element from the cover and the dirt
catch tray from the element.
5.
Remove the dirt catch tray.
6.
Remove the filter element from the filter
bowl cover.
Dispose of the old filter element according
to local regulations and guidelines.