![Hyd-Mech V-25APC Скачать руководство пользователя страница 43](http://html.mh-extra.com/html/hyd-mech/v-25apc/v-25apc_manual_2191216043.webp)
2.13
MECHANICAL CONTROLS
HEAD FORWARD LIMIT SETTING
The Head Forward Limit is factory set and under normal op-
erating conditions should not need to be reset. It functions by
stopping head advance and shutting off the blade when it has
advanced to meet the left hand movable vise jaw.
TO SET LIMIT:
If adjustment of the head stopping position with respect to the
vise jaw is necessary, the split shaft collar on the vise cylinder
shaft may be loosened and the collar re-positioned as neces-
sary.
HEAD BACK LIMIT SETTING
The machine has a 5.6° canted head which requires the head back limit setting to be adjusted according to the height of
material to avoid interference between the blade and the work piece (The head needs to be retracted further for higher
material). The head needs to be adjusted to allow the material to slide freely along the fixed vises. This is achieved by
setting the Head Back Adjustment Pull Cable located on the front of the control console. Pulling the handle out will pull the
limit switch further back, which in turn will allow the head to be retracted further.
The head needs to be
retracted far enough
to allow the material to
slide freely along the
fixed vises.
Interference
Содержание V-25APC
Страница 2: ......
Страница 13: ...0 9 ...
Страница 16: ...0 12 ...
Страница 59: ...4 1 ELECTRICAL SCHEMATICS SEE PDF ON ATTACHED CD SECTION 4 ELECTRICAL ...
Страница 60: ......
Страница 63: ...6 1 MECHANICAL ASSEMBLY DRAWINGS PARTS LIST SEE PDF ON ATTACHED CD SECTION 6 MECHANICAL ASSEMBLIES ...
Страница 64: ......
Страница 72: ...8 2 V 25APC 5 BARFEED LAYOUT SHEET 1 ...
Страница 73: ...8 3 V 25APC 5 BARFEED LAYOUT SHEET 2 ...
Страница 74: ...8 4 V 25APC 10 BARFEED LAYOUT SHEET 1 ...
Страница 75: ...8 5 V 25APC 10 BARFEED LAYOUT SHEET 2 ...
Страница 76: ...8 6 ...
Страница 78: ......