![Hyd-Mech V-25APC Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/hyd-mech/v-25apc/v-25apc_manual_2191216029.webp)
1.13
HYDRAULIC OIL
The V-25 APC bandsaw is supplied with Texaco Rando HD46 oil. If it is necessary to change the oil to a different brand it
is good practice to empty the hydraulic tank using a pump. Fill the hydraulic tank approximately 1/3 full with the new brand
of oil and operate the saw through several cycles with maximum cylinder extension. Drain the hydraulic tank again and
then refill to capacity with the new brand.
CUTTING FLUID
As the V-25 APC operates with an open reservoir to contain the cutting fluid, no cutting fluid can be shipped with the saw.
There are two main types of cutting fluids available, oil based and synthetic. For oil based fluids the dilution ratio is 1:10.
One part concentrate to ten parts water. For synthetic cutting fluids dilution, if required, should be done to the specifica
-
tions as recommended by the manufacturer.
WIRING CONNECTIONS
After the machine is levelled and anchored the necessary power hook-up
needs to be performed. In order to provide safe operation as well as to
prevent potential damage to the machine, only qualified personnel should
make the connections.
BEFORE START-UP THE FOLLOWING TWO POINTS SHOULD BE
CHECKED
1.
Signs of damage that may have occurred during shipping to the
electrical cables and the hydraulic hoses.
2.
The hydraulic oil level is between the upper and lower levels on
the gauge.
As supplied, the machine is set to run on three phase voltage as indicated
on the serial plate and voltage label.
During the initial hook-up, it is very important to check that the phase order is correct. This is indicated by the hydraulic
system pressure gauge registering a pressure rise and the blade running in a counter clockwise direction. If the hydraulics
do not register an immediate pressure rise,
SHUT THE HYDRAULICS OFF
and change the phase order.
ATTENTION: Running the hydraulics “backwards” can damage the hydraulic pump!
Power connection to the machine is made to the L1, L2, L3 and ground terminals located inside the control panel above
the fuse holders as shown in the photo.
BLADE TENSION CHECK
When the machine is first started, the blade position must be checked. Check that the blade teeth do not project more
than 1/4” beyond the front face of both the drive and idler wheel. If it is consult “Blade Tracking” in Section 3. If it has
stayed in it’s correct position, then check that the blade tension switch is in the “+” position and close the door.
Blade tension switch
L1, L2, L3
Содержание V-25APC
Страница 2: ......
Страница 13: ...0 9 ...
Страница 16: ...0 12 ...
Страница 59: ...4 1 ELECTRICAL SCHEMATICS SEE PDF ON ATTACHED CD SECTION 4 ELECTRICAL ...
Страница 60: ......
Страница 63: ...6 1 MECHANICAL ASSEMBLY DRAWINGS PARTS LIST SEE PDF ON ATTACHED CD SECTION 6 MECHANICAL ASSEMBLIES ...
Страница 64: ......
Страница 72: ...8 2 V 25APC 5 BARFEED LAYOUT SHEET 1 ...
Страница 73: ...8 3 V 25APC 5 BARFEED LAYOUT SHEET 2 ...
Страница 74: ...8 4 V 25APC 10 BARFEED LAYOUT SHEET 1 ...
Страница 75: ...8 5 V 25APC 10 BARFEED LAYOUT SHEET 2 ...
Страница 76: ...8 6 ...
Страница 78: ......