Door Phone Interface
Description
The door phone interface allows connection of a door phone unit to the TD Series digital telephone
system. Each Single Line Station Card will accommodate (1) door phone interface. An alternative to the
traditional Door Phone interface is the Access Control Phone that attaches to a digital station port. For
more than one Doorphone and additional information see Access Control Phone.
Conditions
Requires connection to door phone(s) to become operable.
Programming
Mode 03- Doorphone Station ring assignment
Mode 05-03-08- Doorphone Ring Pattern
Mode 05-11-07- Doorphone Ring Time Duration
Mode 05-12-04- Door Phone Relay Activation Timer
Mode 46-ST-06- Station unlock access
Mode 06-01-fn- Relay Assignment for Doorphone
Ringing Stations- Mode 03-[Door phone #]-[STN (s)], Door Ring Assignment must be programmed to
select the stations that will ring when the door phone pushbutton is pressed. The door phone can have
up to eight stations assigned to ring when the door phone pushbutton is pressed.
Ring Pattern- Mode 05-03-08 parameter allows for different ring patterns for assigned ringing stations
when the doorphone is activated.
05-03-08 -Doorphone Ringing Frequency.
This parameter allows for different ring patterns for the Door Phone
0= continuous ringing
1~8 = ring frequency of the DK
telephone
9= Background Music
Ring Duration- The length of the ringing signal for Door Phone notification is programmable. Mode 05-11-
07 provides control of the length of time. Default is 10 seconds. Valid settings are:
05-11-07 - Door Phone Ring Timer
This parameter sets the time that Door Phone ring assigned stations will ring for when the Door
Phone button is pressed.
0=5 seconds
1=10 seconds
2=15 seconds
3=20 seconds
4=25 seconds
5=30 seconds
6=35 seconds
7=40 seconds
8=45 seconds
9=50 seconds
Relay Activation- If it is necessary to control a latch release or other switching device in conjunction with a
door phone, Mode 06-[Relay#], Relay Assignment must be set to 02 to be associated with door phone.
The G1-MSC card has 1 dry contact relay.
No voltage is provided by the system, the installer will have to provide their own source to suit the
application. Only use the relays to switch 24V. They are only designed for low voltage control circuits. All
Relays are Normally Open contacts and will close on activation of the function for which they have been
programmed.
Assign the required Relays one of the following functions.
Valid Settings (06-01)
00=Non-Operational (Default)
04=Trunk Loud Bell
01=Music On Hold
05=Station Loud Bell
02=Door Latch Release
06=System Alarm
Содержание G1 8-24
Страница 191: ...191 DISA With No Voice Service Unit Chart 1 ...
Страница 192: ...192 DISA With No Voice Service Unit Chart 2 ...
Страница 193: ...193 DISA With No Voice Service Unit Chart 3 ...
Страница 194: ...194 DISA With a Voice Service Unit Chart 1 ...
Страница 195: ...195 DISA With a Voice Service Unit Chart 2 ...
Страница 196: ...196 DISA With a Voice Service Unit Chart 3 ...