Date and Time Setting (cannot be accessed through SM)
Description
For the purposes of Station Message Detail Recording and for digital telephone sets equipped with Liquid
Crystal Displays, Time of Day, Day of Week, Date, Month, and Year are stored by the system. A built in
battery provides battery backup for this information as well as system database backup. In the event of a
power failure, the battery cell will keep all information and continue to operate the real time clock for a
minimum of 1200 hours.
Conditions
None
Programming
Initial programming of time, day and date information may be programmed on Mode 11. The format of
this entry is as follows:
MM DD YY
hh mm d
MM=Month (01-12)
DD=Day of Month (01-31)
YY=Year (00-99)
hh=hour (00-23)
mm=minutes (00-59)
d=day of week
Note:
Day of week schedule: 1=Monday
2=Tuesday
3=Wednesday 4=Thursday
5=Friday
6=Saturday
7=Sunday
The operator console also has the option of programming the same information without the requirement
to enter system programming. The procedure follows:
1.
Operator idle. Press [PRG].Press [HOLD].
2.
Press 7
3.
Press [SAVE].
4.
Enter information in format listed above.
5.
Press [SAVE].
6.
Lift and replace the telephone handset.
Operation
None
Содержание G1 8-24
Страница 191: ...191 DISA With No Voice Service Unit Chart 1 ...
Страница 192: ...192 DISA With No Voice Service Unit Chart 2 ...
Страница 193: ...193 DISA With No Voice Service Unit Chart 3 ...
Страница 194: ...194 DISA With a Voice Service Unit Chart 1 ...
Страница 195: ...195 DISA With a Voice Service Unit Chart 2 ...
Страница 196: ...196 DISA With a Voice Service Unit Chart 3 ...