79
Door Unlock Relay Activation Time- Mode 05-12-04
This parameter sets the time that the door unlock relay will remain activated after the Door Unlock
function is activated by the user. The Door unlock relay is programmed in Mode 06.
05-12-04 – Door Relay Activation Timer
This parameter sets the time that the door unlock relay will remain activated after the Door Unlock
function is activated by the user. The Door unlock relay is programmed in Mode 06
0=1 second
1=2 seconds
2=3 seconds
3=4 seconds
4=5 seconds
5=6 seconds
6=7 seconds
7=8 seconds
8=9 seconds
9=10 seconds
Door Unlock Access-Mode 46-ST-06 defines whether or not a station user has the authority to use the
unlock feature.
Feature
0 1 2 3 4 5 6 7
Door Unlock
D A D A D A D A
Do Not Disturb D D A A D D A A
Call Forward
D D D D A A A A
D= Disallow
A=Allow
Operation
To place a call from a door phone.
1. Press door phone button. Pre-programmed stations ring.
2. Ringing stations may answer the door phone by going off hook. Non ringing stations must
answer the door phone by dialing 88.
3. Door phone acts as speaker phone for duration of call. Door phone is under control of answering
station.
To call door phone from any station.
1. Station user goes off hook or activates speaker phone (if equipped).
2. Station user dials 88 to reach door phone.
See also, Door Phone Controlled Switch, page 80 of this document.
Содержание G1 8-24
Страница 191: ...191 DISA With No Voice Service Unit Chart 1 ...
Страница 192: ...192 DISA With No Voice Service Unit Chart 2 ...
Страница 193: ...193 DISA With No Voice Service Unit Chart 3 ...
Страница 194: ...194 DISA With a Voice Service Unit Chart 1 ...
Страница 195: ...195 DISA With a Voice Service Unit Chart 2 ...
Страница 196: ...196 DISA With a Voice Service Unit Chart 3 ...