MI91.2270
25JUN98
GROUND CABLE INSTALLATION
FOR FENNER STONE PUMPS
3/8" EXTERNAL
STAR
3/8-16 X 3/4
HHCS
RAP0838 GROUND STRAP KIT
GROUND
CABLE
MOTOR
A
B
CONNECT GROUND CABLE STRAP FROM NEGATIVE ("-")
MOTOR TERMINAL TO PUMP CHANNEL MOUNTING BOLT
(A). IF PUMP CHANNEL IS WELDED TO FRAME , CONNECT
GROUND CABLE STRAP TO A PUMP MOUNTING BOLT (B).
A 3/8" EXTERNAL STAR LOCK WASHER MUST BE USED BE-
TWEEN GROUND CABLE STRAP TERMINAL/PUMP CHANNEL
AND BETWEEN GROUND CABLE STRAP TERMINAL/BOLT
SEE DETAIL "A"
DETAIL "A" SIDE VIEW
CABLE
GROUND
PRESSURE SWITCH WIRE
RELAY GROUND WIRE
LOCK WASHERS (2)
HEAD OR NUT.
+
-
GROUND WIRE
PRESSURE SWITCH WIRE
(IF APPLICABLE)
(IF APPLICABLE)
(610 SYSTEMS ONLY)
(NOT NEEDED WITH 200 SYSTEMS)
LOCK WASHER
STAR
LOCK WASHER
3/8" EXTERNAL
SEE OPERATOR’S MANUAL FOR CONNECTION INFORMATION OF GROUND WIRES AND SOLENOIDS.