MI91.2248
25JUN98
WITH SHRINK TUBE TO SEAL.
BUTT CONNECTOR THEN COVER COMPLETELY
TUBE. IF SOLDERING IS NOT POSSIBLE USE A
INSULATE AND SEAL CONNECTION WITH SHRINK
IF SPLICE IS REQUIRED , SOLDER WIRES THEN
BOTH SIDES OF TERMINAL AND UNDER NUT.
DIRECT TO CHASSIS FRAME RAIL.
WHITE GROUND WIRE MUST BE GROUNDED
GROUNDING INSTRUCTIONS
3) IMPORTANT: PLACE INTERNAL LOCK WASHERS ON
4) SEAL BOTH SIDES WITH SILICONE CAULKING.
1) GRIND FRAME RAIL CLEAN.
2) DRILL 1/4" DIAMETER HOLE.
RAP0999 BOX GROUND KIT
610 CONTROL BOX
GROUNDING INSTRUCTIONS
BROWN - ACCESSORY
WHITE - GROUND
BROWN - ACCESSORY
LOCK WASHER
GROUND WIRE MUST RUN
DOWNWARDS FROM CONNECTION
TO PREVENT WATER BUILDUP
BETWEEN TERMINAL AND CHASSIS.
CHASSIS FRAME RAIL
NO SUBSTITUTIONS