REPAIR STEPS
SOLUTION
DIAGRAMS
PROBLEM
MI91.2240
02JUL98
REFER TO MP85.5092
5 AMP
10 AMP
10 AMP
5 AMP
5 AMP
10 AMP
10 AMP
REFER TO MP85.5043
Part 6
REFER TO MP75.5010
Part 8
AIR DUMP FUSE
AIR DUMP SOLENOID
REFER TO MP85.5043
a. Air will not dump
from the suspen-
sion.
With the leveling system off and the ignition on, check the wire going
to the air dump valves for +12 volts while the dump button is being
pushed. If +12 volts is present, check the ground for the valve then
replace the valve. If +12 volts is not present, check the 5 amp air dump
b. Air dump valves
will not close.
With the ignition on, check the gray wire in the 9 pin UML connector
at the box. If +12 volts is present, replace the control box. If +12 volts
is not present, replace the air dump valve.
Part 7
Yellow level in-
dicator lights do
not work proper-
The sensing unit is a 4 inch diameter disk that is usually mounted on
the under side of the coach towards the middle of the coach. Occasion-
ally it will be found inside the coach or in a storage compartment. Check
that the unit is not mounted, nor the wires routed near a heat source.
Check that the sensing unit is mounted correctly according to the stick-
er on the sensing unit. The sensing unit is adjusted by drawing up the
corresponding screws (if the sensing unit is mounted under the coach)
to put out the yellow lights. Unplug the sensing unit at the control box.
Using a 12 volt test light connected to ground, touch each pin in the
control box for the sensing unit. Check that the proper yelllow light on
the touch panel comes on when its pin is touched. Only one light should
The first part of
automatic leveling
was covered in
Part 1 through 4
of this Section.
AUTOMATIC LEVELING
Part 9
After pushing the
"I" button a third
time:
a. The red indica-
tor light does not
flash.
If the low volts indicator comes on recheck Part 4b of the Section. If
the low volts indicator does not come on the problem is the touch panel
or the control box.
b. The air does not
dump at this time.
(If applicable.)
Recheck Part 6a of this Section. If the air will dump manually but not
automatically, replace the control box.
WHITE GND
YELLOW LS
BLACK FRONT
GREEN RD
RED REAR
SENSOR
fuse. If the fuse is blown, the dump valve wire or one of the dump
valves is shorted to ground. If the fuse is not blown, check for +12 volts
on the gray wire in the 9 pin UML connector at the control box. If +12
is not present replace the control box. NOTE: Some air dump valves
are equipped with an emergency shut off valve. Make sure this valve
is open.
light when a pin is touched. Connect the test light to a +12 source.
Check that there is a ground on the ground pin for the sensing unit. If
there is a malfunction here, replace the control box. If the control box
is ok, replace the sensing unit. Remember to keep the sensing unit
away from any heat source.
ly.