9 SHOCK ABSORBER, SWINGARM
68
Clamp the control lever as shown in the figure.
✓ The
External tank
fD
control lever is
on
Closed, Damper
C,
on Vacuum,
and
Oil reservoir
0
on Vacuum.
Operate the
On/Off
switch (D.
✓ The vacuum pump process starts.
✓ Pressure gauge @ drops to the specified value.
I < 0 bar
✓ The vacuum gauge fa) falls to the specified value.
14
mbar
Measure distance
f)
between the floating piston and reser
voir hole with the special tool.
I Depth micrometer (T107S) (
a
p. 329)
✓ The floating piston is positioned all the way at the bot
tom.
When the vacuum pressure gauge reaches the specified
value, turn the
Oil reservoir
control lever
0
to
Equalize pressure.
Guideline
14
mbar
✓ The pressure gauge increases to the specified value.
0 bar
When the pressure gauge reaches the specified value, turn
the
Damper
control lever
C,
to Pressure.
Guideline
0 bar
✓ Oil is pumped into the damper.
✓ The pressure gauge increases to the specified value.
3 bar
When the pressure gauge reaches the specified value, turn
the
Damper
C,
control lever to
Vacuum.
Guideline
3 bar
✓ The pressure gauge drops to the specified value.
0 bar