15 WIRING HARNESS, BATTERY
15.3
128
Checking the starter rela�
Removing the battery
Warning
Preparatory work
(FE EU/AU)
- Press and hold the kill switch � while the engine is idling
until the engine stops.
- Remove the seat. (
a
p. 92)
- Remove the air filter box cover. (
a
p. 87)
Main work
- Disconnect the negative cable of the battery.
- Pull the starter relay off of the bracket.
- Pull off connector
O.
- Disconnect cables
8
and (Don the starter relay.
- Connect the starter relay to a 12 V power supply as per the
figure.
- Measure the resistance between the specified points.
I Resistance of open circuit I O Q
If the value displayed does not meet specifications:
- Change the starter relay.
Risk of injury
Battery acid and battery gases cause serious chemical burns.
- Keep batteries out of the reach of children.
- Wear suitable protective clothing and safety glasses.
- Avoid contact with battery acid and battery gases.
- Keep sparks or open flames away from the battery.
- Only charge batteries in well-ventilated rooms.
- Rinse the affected area immediately with plenty of water in the event of contact with the skin.
- Rinse eyes with water for at least 15 minutes and consult a doctor immediately if battery acid and
battery gases get into the eyes.
Preparatory work
(FE EU/AU)
- Press and hold the kill switch � while the engine is idling
until the engine stops.
(FE US)
- Press and hold the kill switch � while the engine is idling
until the engine stops.
- Remove the seat. (
a
p. 92)
..
Содержание F2103P4