7
Hydraulics
Inspection, care and maintenance
177
Pic. 38
Loading bridge secured
1
Lift limitation valve
2
Lifting off-switch
3
Adjustment screw, tilting sideways
4
Adjustment screw, tilting towards the rear
5
Counter-nuts
The lift limitation valve is factory-
set to a tilting angle of approx.
50°. Unauthorised adjustment of
the stroke limitation is not
permitted!
Check that the adjustment screws
(Pic. 38 /3 and Pic. 38 /4) are tight.
Fasten the nuts as required and
counter them with counter-nuts
(Pic. 38 /5).
Pic. 39
Upper mounting
1
Ball
2
Grease nipple
3
Screw connection
Visually inspect the upper mounting
for deformation, crack formation.
Tighten the screw connections
(Pic. 39 /3) as required.
Lubricate the ball (Pic. 39 /1) at the
grease nipple (Pic. 39 /2).
Wipe off excess grease.
Pic. 40
Loading bridge tipped to the side
1
Loading bridge
2
Securing cord
Tilt the loading bridge down
(Pic. 40 /1) towards the right and then
towards the left.
Check the appropriate function of the
telescopic cylinder and the switch-off
function.
Check that the securing cable
(Pic. 40 /2) is not pulled tight.
W - 077
2
1
4
5
3
W - 030
1
2
3
W - 078
2
1
Содержание 10000 Series
Страница 1: ...HTK OPERATING INSTRUCTIONS 10000 SERIES EN MACHT S MÖGLICH Three way tipper 195024 xx humbaur com ...
Страница 6: ...Contents 4 ...
Страница 11: ...9 1 Safety ...
Страница 28: ...Personal protective equipment rules prohibitions 26 Safety 1 ...
Страница 29: ...27 2 General information ...
Страница 39: ...37 3 Operation ...
Страница 61: ...59 4 Operating the chassis ...
Страница 102: ...100 Operating the chassis Warning tables optional 4 ...
Страница 103: ...101 5 Operating the body ...
Страница 144: ...5 Roll up tarpaulin optional 142 Operating the body ...
Страница 145: ...143 6 Electrical system ...
Страница 158: ...6 TIM iTAP 156 Electrical system ...
Страница 159: ...157 7 Inspection care and maintenance ...
Страница 218: ...7 Disposal 216 Inspection care and maintenance ...
Страница 219: ...217 8 Troubleshooting ...