![Hubner AMP 41 Скачать руководство пользователя страница 73](http://html1.mh-extra.com/html/hubner/amp-41/amp-41_operating-and-assembly-instructions-manual_2180893073.webp)
Absolute Encoder AMP(H) 41
AMP(H)41_MANUAL-en_R11 - 2019-03-28
73
The Runtime Group is defined with the function
FC1
. In the field
Max. cycle time of
the F-runtime in ms:
enter the value
400
and confirm with
OK
. Also confirm the next
window
Edit F-Runtime Groups
with
OK
.
The programming and modifications are now complete.
8.5
Generating the safety program
To generate the safety program, in
SIMATIC Manager
,
Options
Edit safety
program
menu, open the
Safety Program
dialog. The safety program is compiled and
generated with the
Compile
switch.
If compilation is successful 0 warnings are displayed, and the windows can then be closed.