28
AMP(H)41_MANUAL-en_R11 - 2019-03-28
Absolute Encoder AMP(H) 41
5.3
Connection
NOTICE!
Destruction, damage and malfunction of the measuring system in case of
infiltration of damp!
- In case of storage as well as in the operation of the measuring system unused
connecting plugs have to be provided either with a mating connector or with a
protective cap. The IP protection class is to be selected according to the
requirements.
- Protective cap with O-ring: In case of re-close of the protective cap the existence
and the correct seat of the O-ring have to be checked.
- Corresponding protective caps
see chapter 16.6 “Accessories“ on page 99
Fig. 5: Connector assignment
5.3.1
Supply voltage
NOTICE!
Danger of unnoticed damage to the internal electronics, due to
unacceptable overvoltages!
If an overvoltage of >36 V DC is inadvertently applied, the measuring system
must be checked in the factory. The measuring system is permanently switched
off for safety reasons, if the overvoltage is applied for more than 200 ms.
–
The measuring system must be shut down immediately.
–
When sending the measuring system to the factory, the reasons and circum-
stances relating to the overvoltage must be specified.
–
The power supple used must meet the requirements of
SELV/PELV (IEC 60364-4-41:2005).
X1
Signal
Description
Pin, M12x1, 4 pole
1
+ 24 V DC (13…27 V DC)
Supply voltage
2
N.C.
-
3
0 V
GND
4
N.C.
-
Cable specification: min. 0.5 mm
2
, shielded