![Hubner AMP 41 Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/hubner/amp-41/amp-41_operating-and-assembly-instructions-manual_2180893055.webp)
Absolute Encoder AMP(H) 41
AMP(H)41_MANUAL-en_R11 - 2019-03-28
55
8.1
Prerequisites
WARNING!
Danger of deactivation of the fail-safe function through incorrect
configuration of the safety program!
The safety program must be created in conjunction with the system
documentation provided by SIEMENS for the software and hardware.
Extensive documentation on "Configuring and Programming" a safe
control is provided by SIEMENS in its manual S7 Distributed Safety -
Configuring and Programming, document order number:
A5E00109537-04. This documentation is a constituent of the optional
package
S7 Distributed Safety
.
The following descriptions relate to the pure procedure and do not take
account of the instructions from the SIEMENS manual.
It is therefore essential to observe and comply with the information and
instructions provided in the SIEMENS manual, particularly the safety
instructions and warnings.
The configuration shown should be taken as an example. The user is
required to check and adapt the usability of the configuration for his own
application. This also includes the selection of suitable safety-oriented
hardware components and the necessary software prerequisites.
Software components used for the
S7 Distributed Safety
configuration example:
●
STEP 7 V5.5 + SP2
●
S7 Distributed Safety Programming V5.4 + SP5
●
S7 F ConfigurationPack V5.5 + SP9
Hardware components in the SIMATIC 300 series used for the
S7 Distributed Safety
configuration example:
●
Rail
●
Power supply "PS307 2A" (307-1BA00-0AA0)
●
F-CPU unit "CPU317F-2 PN/DP" (317-2FK13-0AB0)
●
Digital output module "SM 326F DO 10xDC24V/2A" (326-2BF01-0AB0),
is not actively used in the following safety program and is intended for customer-specific
outputs, e.g. to show the variable states of the F-Periphery-Block:
PASS_OUT, QBAD, ACK_REQ, IPAR_OK etc.
●
Digital input module "SM 326F DI 24xDC24V" (326-1BK01-0AB0),
is used for the operator acknowledgment.