![Huawei UPS2000-G-3 kVA Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/huawei/ups2000-g-3-kva/ups2000-g-3-kva_user-manual_166642020.webp)
UPS2000-G-3 kVA
User Manual (CTC)
2 Quick Introduction
Issue 02 (2019-05-05)
Copyright © Huawei Technologies Co., Ltd.
14
Silk
Screen
Definition
Description
Alarm Status
overvoltage lockout, discharge overcurrent lockout,
discharge overcurrent protection, and cell 1–
N
fault alarm
DO2
Overload warning,
overdischarge
protection,
overdischarge
If the ESM raises one of the following alarms, the dry
contact supplies an alarm signal:
Discharge undervoltage alarm, discharge undervoltage
protection, discharge due to single-ESM cell low voltage
disconnection, and heavy load warning
Table 2-5
Indicator description
Silk
Screen
Indicator
Color Status
Description
RUN
Running
indicator
Green
Steady on
Communication is normal (including board startup,
self-check, software loading, and board power-on when
not loaded; excluding sleep when the power port or PWR
port is energized).
Off
The ESM is in sleep mode.
Blinking at
0.5 Hz
The LCD user interface (LUI) is querying data.
Blinking at
4 Hz
Communication is disconnected.
ALM
Fault indicator
Red
Steady on
There is a fault or major alarm.
Off
There is no fault or major alarm.
CHG
Charge
indicator
Green
Steady on
The ESM is being charged.
Off
The ESM is open-circuited or discharging.
DCHG
Discharge
indicator
Green
Steady on
The ESM is discharging.
Off
The ESM is open-circuited or being charged.
NOTE
Major alarm: The ESM needs to be maintained immediately.
Minor alarm: The ESM does not require maintenance, but sends a reminder to remote maintenance personnel.
Blinking at long intervals: on for 1s and then off for 1s
Blinking at short intervals: on for 0.125s and then off for 0.125s
All indicators are blinking: The ESM has entered the maintenance mode.
When the ESM is in sleep mode, the fault indicator is off except for reverse-connection protection.