User Manual
7 WebUI
Issue 12 (2019-01-15)
Copyright © Huawei Technologies Co., Ltd.
201
Running parameters
Figure 7-22
Running parameters
Baud rate
is set to
115200
by default, which provides optimal communications performance and
does not need to be changed.
If
Anti-crosstalk
is set to
Enable
, the inverter with a PLC STA in the SN list can access networking.
Parameters
Box-type transformer No.
and
Winding No.
can be set for the PLC CCO with
SUN2000 V100R001C72SPC100 or later versions. In multi-split transformer scenarios, specify
Winding No.
based on the actual winding number of the SmartLogger connected to the transformer.
When the box-type transformer and winding numbers of the inverter with an STA are consistent with
those of the PLC CCO, the inverter can access networking.
SN list
Figure 7-23
SN list
The SN list displays the relevant information of the inverters with PLC STAs that can be connected.
Tap
Synchronize
, and synchronize the box-type transformer and winding numbers of the PLC CCO
to the inverter.