SmartLogger1000
User Manual
7 WebUI
Issue 12 (2019-01-15)
Copyright © Huawei Technologies Co., Ltd.
172
Protection Parameters
Table 7-4
Parameter description
No.
Parameter
Description
Unit
Value Range
1
Insulation
resistance
protection
To ensure device safety, the
inverter detects the insulation
resistance of the input side to the
ground when it starts a self-check.
If the detected value is less than
the preset value, the inverter does
not export power to the power
grid.
MΩ
The value range for the 600 V
inverter is [0.02, 1.5], that for
the 1000 V inverter is [0.033,
1], and that for the 1100 V
inverter is [0.033, 1.5].
Feature Parameters
Table 7-5
Parameter description
No.
Parameter
Description
Unit
Value Range Remarks
1
MPPT
multi-peak
scanning
When the inverter is used in
scenarios where PV strings are
obviously shaded, enable this
function. Then the inverter will
perform MPPT scanning at
regular intervals to locate the
maximum power.
N/A
Disable
Enable
The scan interval is
set through
MPPT
scanning interval
.
2
MPPT
scanning
interval
Specifies the MPPT scan
interval.
min
[5, 30]
This parameter is
displayed only when
MPPT multi-peak
scanning
is set to
Enable
.
3
RCD
enhancing
RCD refers to the residual
current of the inverter to the
ground. To ensure device
security and personal safety,
RCD should comply with the
standard. If an AC switch with a
residual current detection
function is installed outside the
inverter, this function should be
enabled to reduce the residual
current generated during
inverter running, thereby
preventing the AC switch from
misoperations.
N/A
Disable
Enable
N/A