4 Electrical Connections
Issue 12 (2019-01-15)
Copyright © Huawei Technologies Co., Ltd.
35
Figure 4-13
Connecting the SmartLogger to the SUN2000
Procedure
Step 1
Prepare a cable with an appropriate length, strip a proper part of the insulation layer from one
end, and connect the end to the SUN2000 terminal block.
The DJYP2VP2-22 2x2x1 network cable or a communications cable with a cross
sectional area of 1 mm
2
and outer diameter of 14–18 mm is recommended.
For details about how to strip and connect the cable, see the SUN2000 user manual.
Step 2
Strip an appropriate length from the other end of the cable using a wire stripper, as shown in
Figure 4-14
Stripping an RS485 communications cable (unit: mm)
Step 3
Insert the bare core wires into the surge port of the RS485 signal SPD, as shown by (1) in