SmartACU2000B smart array controller
User Manual (with PID modules, 800 V AC)
5 Electrical Connections
Issue 05 (2019-01-20)
Copyright © Huawei Technologies Co., Ltd.
77
5.13 Connecting the 24 V DC Output Power Cable
Context
You can connect one or two 24 V DC output power cables to the smart array controller that
supports 24 V DC input and output. DC output power cables are connected in the same
manner. This section describes how to connect one route of DC output power cable.
Table 5-2
Mapping
No.
Port on the JX02 Terminal
Block
Definition
1 and 2
Positive terminal of the 24 V DC
output power cable
3 and 4
24VOUT–
Negative terminal of the 24 V
DC output power cable
Procedure
Step 1
Prepare cables.
Figure 5-26
Stripped cable length
Step 2
Connect the 24 V DC output power cable to the JX02 terminal block.
Do not connect the DC output power cable reversely.
Step 3
Bind cables.