2 Establishment of the Configuration Environment
Quidway NetEngine20/20E
Configuration Guide - Basic Configurations
2-8 Huawei
Proprietary
and Confidential
Copyright © Huawei Technologies Co., Ltd.
Issue 05 (2010-01-30)
Configuration Roadmap
1.
Connect the PC and the router through the console port
2.
Configure the parameters on the PC end
3.
Log in to the router
Data Preparation
Terminal communication parameters (including baud bit, data bit, parity, stop bit and flow
control).
Configuration Procedure
Step 1
Connect the serial port of the PC (or terminal) to the console port of the router through
standard RS-232 configuration cable. The local configuration environment is established.
Step 2
Run the terminal emulation program on the PC. Set the terminal communication parameters to
be 9600 bps, data bit to be 8, stop bit to be 1. Specify no parity and no flow control as shown
from
Figure 2-2
to
Figure 2-4
.
Figure 2-2
New connection