![Huawei Quidway NetEngine 20 series Скачать руководство пользователя страница 203](http://html.mh-extra.com/html/huawei/quidway-netengine-20-series/quidway-netengine-20-series_configuration-manual_169449203.webp)
Quidway NetEngine20/20E
Configuration Guide - Basic Configurations
10 Router Maintenance
Issue 05 (2010-01-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
10-7
The system view is displayed.
Step 7
Run:
slave switchover
The master/slave switchover is performed forcibly.
Ensure the router works normally.
----End
10.4 Monitoring the Router Status
In the daily maintenance of the router, you need to use the
display
commands to know the
status of the router. This section covers the following topics
z
Displaying the Basic Device Information
z
Displaying the System Version Information
z
Displaying the Restart Information of RPU
10.4.1 Displaying the Basic Device Information
NE20 does not support the
abnormal
parameter in this chapter.
Run:
display
device
[
slot-id
|
abnormal
]
The basic device information is displayed.
Using the preceding command, you can check the current boards in service and find out
which board is faulty.
10.4.2 Displaying the System Version Information
Run:
display
version
[
slot-id
]
The system version information or the version information of the board in specified slot is
displayed.
Using the preceding command, you can check the system file version and the parameters of
each board. For example:
<Quidway>
display version
Huawei Versatile Routing Platform Software
VRP (R) Software, Version 5.30(NE20 V200R005C03SPC001)
Copyright (c) 2000-2007 HUAWEI TECH CO., LTD.
Quidway NetEngine 20E-8 Router uptime is 0day, 0hour, 30minutes
Startup time : 2007/03/28 13:48
Master Rpu (9)'s version information: