IPC6521-Z20-FI 1080P Intelligent Network Speed
Dome
User Guide
5 Device Configuration
Issue 02 (2013-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
56
Step 5
Click
Add
and draw points on the live video image to form a sensitive area.
To delete a sensitive area, select the sensitive area ID from the sensitive area list (only the selected
sensitive area is displayed in white on the live video image), click
Delete
.
A sensitive area can be a polygon of three vertices or more.
A sensitive area can have a maximum of 10 vertices.
A single behavior analysis function supports up to four sensitive areas. If all functions are enabled, a
maximum of 10 sensitive areas can be analyzed at a time.
You can perform operations on only one sensitive area at a time.
A maximum of 15 and 30 objects can be analyzed in close-up object and distant object modes
respectively.
When the resolution is set to 352 x 288, the system can analyze objects with a minimum size of 10 x
10, and a maximum size of 100 x 100 and 100 x 200 in distant object and close-up object modes
respectively. The values indicate limitations on the object area instead of the object's length or
height.
Step 6
Set
Name
.
Step 7
Click
Save
.
The abandoned object detection function is configured.
----End
Verification
When an individual enters the sensitive area and leaves an object in the area for more than 10
seconds:
If the object is marked with a red box on the live video image, abandoned object
detection is successfully configured.
If the object is not marked on the live video image, abandoned object detection is not
properly configured or not enabled.
Table 5-14
lists the possible causes and their
solutions.
Table 5-14
Possible causes
Cause
Solution
The surveillance area is too large.
Adjust the focal length and dimensions of
the surveillance area to ensure that the
intended object can be detected.
The surveillance area is too small.
The behavior analysis function is disabled.
Enable the behavior analysis function.
The sensitive area is not in
Enable
state
when
Behavior type
is set to
Abandoned
object detection
on the
Behavior Analysis
Parameters
page.
Select the sensitive area ID from the
sensitive area list and click
Enable/Disabled
to enable the sensitive
area.
Video alarm deployment
is not selected on
the
Alarm Deployment Policy
page that is
displayed when you choose
Settings
>
Alarm Configuration
>
Alarm
Deployment Policy
.
Select
Video alarm deployment
.