4. In case of measurement with optional accessory
IMP57
it is necessary to use the
adapter cable (optional accessory
C2009AD
) for the connection to the USB2 or
USB3 ports of the instrument. To carry out the measurement, refer to the user
manual of the IMP57 accessory
5. Check selected limit mode (STD, kA, I
2
t, TRIP CURR. or Ut) and modify it if
needed after pressing the
LIMIT
touch-screen key
6. Check other parameters (they depend on selected limit mode) like type of
protection, nominal current, wire material etc. and modify them if needed by
pressing appropriate parameter touch-screen key first
7. Select measurement screen by pressing the
touch-screen key and check all
settings again
8. Connect the test leads or the cable with schuko plug according to one of the
below figures
Fig. 46 : Connection with schuko cable for LOOP
L/N
or LOOP
L/PE
test
Fig. 47 : Connection with test leads for LOOP
L/N
test
Fig. 48 : Connection with test leads for LOOP
P/PE
test