Maintenance of the baling press
5.2.1
Changing the hydraulic fl uid / venting fi lter
Change the hydraulic fl uid and the venting fi lter
every 2 years
– Run the press ram to its rear limit position
– Turn off the main switch and disconnect the red CEE power plug
– Screw off the 2 srews on both sides of the cover (1)
– Take out the spindle (2) with the tape rolls and put it on the ground
– Remove the cover (H)
Venting fi lter
Part. no. 6.116.195.090
– Remove the tank cover and extract the oil with an oil suction unit
• The capacity of the hydraulic fl uid tank is ~ 27 l
– If the tank is very dirty, clean it
– Mount the tank cover onto the unit again
– Add oil until a level between the notches on the oil level dipstick is reached
2
H
1
1