Malfunctions of the baling press
As soon as a malfunction occurs in the baling press, the red malfunction symbol lights
up. The baling press and shredder switch off and the relevant error message appears in
the text display.
The “Baling press status” symbol
lights up red on the shredder.
The error number of the most recent error is stored in the error memory.
Diverse, displayed error messages can be cleared by simultaneously pressing the + / –
keys or by turning the machine on and off.
Service - Hotline: +49 7544 2100-300
4.9.1 Error
numbers
Code
Description
Remedy
1000
One of the phases is missing / power input
Electrician! Check the fuses on site.
1010
A phase is wrong / counter-clockwise phase
rotation
Electrician! Phase sequence on site / check phase
rotation.
1100
Oil temperature too high
Let oil cool down
1110
Defective oil temperature sensor
Electrician! Replace sensor
1200
Motor protective switch has triggered off
Let Motor cool down - ~ 20 min. waiting
1201
Motor protective switch oil cooler has triggered
off
Let Motor cool down - ~ 20 min. waiting
1210
Emergency stop on the press has been activated Unlock the emergency stop button
1211
Emergency stop on the shredder has been
activated
Unlock the emergency stop button
1222
Service door in the fi lling area of the press is
open
Close the inspection fl ap
1223
Strapping fl ap is open
Close strapping fl ap
1271
“Extend press ram” timing
Check the movement of the press ram
1272
“Retract press ram” timing
Check the movement of the press ram
1273
Shearing malfunction
Remove material jam
1274
Compression malfunction
Check channel adjustment
1282
Inductive switch channel adjustment
Electrician! Check inductive switch
1290
Light barrier compression/material bridge
Remove material bridge / clean light barr.
1291
Light barrier overcharging/material bridge (option)
Remove material bridge / clean light barr.
1300
Defective hardware
Electrician! Consult HSM customer service
1310
Short-circuit master output stage
Electrician! Consult HSM customer service
1320
Short-circuit slave output stage
Electrician! Consult HSM customer service