4.6 ELECTRICAL CONNECTIONS
4.6.1 Connectors
In the electrospindle there are two electrical connectors for power and signals respectively; the two
connectors are located in an electrical box also known as the “fixed mounting plate”. A “mobile
mounting plate” is also supplied with the electrospindle, with the mobile connectors to be wired by
the customer. Upon request, pre-wired “mobile mounting plates” are available, with cables of
different lengths.
The position of the electrical connectors is shown in section 2.
4.6.1.1 Layout of POWER connector (fixed part)
PIN DESCRIPTION
1
Thermal alarm
230V AC MAX; 48V DC MAX; 1.6A MAX
2
:
Common PE with PIN 7
3
230V AC 50/60Hz solenoid valve (if
present)
4
U Motor phase
5
Thermal alarm
230V AC MAX; 48V DC MAX; 1.6A MAX
2
5
3
4
6
1
8
9
7
6
Motor V phase
7
:
Common PE with PIN 2
8
Motor W phase
i
Use cables of not less than
6mm
2
(or AWG10) for the even
PINs, and 1mm
2
(or AWG18) for
the odd ones
9
230V AC 50/60Hz solenoid valve (if
present)
The electrical power supply to the electrospindle MUST be provided via inverter.