Kit of gauges to adjust sensors S1 and S4 HSK F63 (code HSD
3811H0110)
A
Thickness spacer for adjusting sensor S1 (0.04mm)
B
Thickness spacer for adjusting sensor S4 (0.12mm)
C
Thickness spacer for adjusting sensor S4 (0.16mm)
D
Gauge for adjusting sensor S1 (14.29mm)
E
Gauge for adjusting sensor S4 (14.13mm)
Figure 8.17 kit for sensors F63 code HSD 3811H0110
For the F63 version of the HSK spindles, the kit of gauges code HSD 3811H0110 is available.
The use of the gauges allows the immediate positioning of the HSK collet in the position in which
the sensors are regulated, thus allowing an adjustment that is not only quicker but also more
precise, given that the gauges have been produced with stricter tolerances compared with the
normal tool-holders.
Although it is possible to carry out the adjustment of the sensors without using the kit as described
in the previous paragraphs, HSD strongly recommends the use of the kit, in view of the importance
(for safety purposes) of the accurate adjustment of the sensors.
The gauges and thickness spacers shown in Figure 8.17 are identified by the indication of the
thickness spacer engraved on their surface, or shown on their packaging label.
Figure 8.18 use of the gauge as a normal tool-
holder, with or without interposed
thickness spacer (Figure 8.19),
according to the indications of
the table shown in the
procedures of paragraphs 0 and
0
Figure 8.19 interposition of the thickness
spacer between the stop
surfaces of the gauge and of the
spindle shaft