7.1.6 Check of functionality collet HSK
Frequency :
6 MONTHS or 2
00
000 tool changes
•
Control the expulsion limit (see limit “ B1” in table 8.1, pag 167)
•
Through a blocked tool tighten the dowel in the expeller
•
Check the tightening strength (using Power Check). If the tightening force is
inferior of 70 % of the nominal value, it is necessary to effect the following operations:
o
grease again , and check again the tightening force
o
change the collet and check again
o
change completey the thightening device
7.1.7 Checking the connections
Frequency:
MONTHLY
Check the integrity of the electrical cables of both power and signals, and also that the connectors
are firmly fixed. Check the seal of the tubes and connectors of the cooling and compressed air
circuits.
7.1.8 Replacing the filters of the pneumatic circuit
Frequency:
ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS
Carry out regular maintenance and replacement of the filters of the pneumatic circuit for the HSD
product, following the manufacturer's indications (see section 4.4)
7.1.9 Bearings
Frequency:
NEVER
THE BEARINGS HAVE BEEN LUBRICATED FOR LIFE AND DO NOT REQUIRE
RECURRENT ADDITIONS OF GREASE.