8.8 REPLACING THE SENSORS
8.8.1 Wiring the sensors of ISO30 models with single-acting piston
S1
PIN 4
PIN 6
S2
PIN 1
S3
PIN 3
PIN 2
3
1
2
Figure 8.1
connection of the sensors of the ISO30 versions to the PINs of the signals connector
8.8.2 Wiring the sensors of HSK models with single-acting piston
S1
S2
S4
4
1
2
PIN 4
PIN 6
PIN 1
PIN 2
14
S3
3
PIN 3
PIN
Figure 8.2
connection of the sensors of the HSK versions to the PINs of the signals connector
NOTE FOR HSK VERSIONS:
the output on PIN “14” must not be used to control
the machine, but only to identify the faulty sensor of the <S1+S4> range in the
event of malfunctioning, and to calibrate sensor S1 as described in paragraphs