Drive support information
Depending on the drive cage installed, the server supports the following drives:
• Non-hot-plug LFF SATA drives
• Hot-plug LFF SATA or SAS drives
• Hot-plug SFF SATA or SAS drives
The server supports up to eight drives in the SFF configuration and four drives in the LFF configuration.
The embedded HPE Smart Array S100i SR Gen10 Controller supports SATA drive installation. For SAS drive installation,
install a type-p standup plug-in Smart Array controller option.
Installing an LFF non-hot-plug drive in the drive cage
Prerequisites
Before you perform this procedure, make sure that you have a T-15 Torx screwdriver available.
Procedure
1.
2.
Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3.
Disconnect all peripheral cables from the server.
4.
Do one of the following:
• If the server is in tower mode:
Position the tower server for hardware configuration.
• If the server is in rack mode:
Remove the server from the rack.
5.
6.
7.
If installed,
8.
If there are drives already installed in the non-hot-plug drive cage,
disconnect all cables from the drives.
9.
Remove the non-hot-plug drive cage:
a. Remove the screws from the drive cage.
b. Remove the non-hot-plug drive cage.
50
Hardware options installation
Содержание ProLiant ML30 Gen10
Страница 19: ...Four bay LFF hot plug drive numbering Eight bay SFF hot plug drive numbering Component identification 19...
Страница 21: ...Component identification 21...
Страница 75: ...10 Remove the mylar tape 11 Attach the serial port cable clip to the chassis Hardware options installation 75...
Страница 111: ...Heatsink fan cabling PCI fan cabling Cabling 111...
Страница 113: ...Front I O cabling Front USB cabling Cabling 113...