Table 56 Error Codes — Part Code 6510
(continued)
Failure
Level
Severity
Level
Recommended Action
Error Message
Error
Number
Part
Code
0
W
Check the check box when
you add the journal group of
the local DKC to the extended
consistency group (EXCTG).
The serial number of the local
DKC is entered. Select the
check box when you add the
journal group of the local
DKC to the extended
consistency group (EXCTG).
59329
6510
0
W
Delete other DKC to use the
journal group of the local
DKC.
The local DKC cannot be
specified for the extended
consistency group (EXCTG).
Delete other DKC to use the
journal group of the local
DKC.
59330
6510
0
W
Check whether the specified
volume is a LUSE volume.
Also, check the version of the
microcode of the storage
system.
A LUSE volume is included in
the specified volumes.
The current version of the
microprogram does not allow
you to create pairs using
LUSE volumes.
59331
6510
0
W
Check the value of the path
watch time.
The value of the path watch
time is not entered or is
outside the range. Check the
value of the path watch time.
59335
6510
0
W
Specify another volume.
The specified volume is not
valid for this program
product. Specify another
volume.
65664
6510
0
W
Check the monitoring setting.
The specified volume is not
the volume to be monitored.
Check the monitoring setting.
65665
6510
0
W
The microcode versions
between the DKCMAIN and
the SVP might not match.
Confirm the microcode
versions of the DKCMAIN
and the SVP.
The current microcode
version of DKCMAIN cannot
assign remote command
devices to mirrors.
65777
6510
0
W
Check if a remote command
device was assigned to the
specified mirror.
No more remote command
devices can be assigned to
the specified mirror.
65778
6510
0
W
Check whether the specified
journal groups include
mirrors available to assign a
remote command device.
There are no mirrors
available to assign a remote
command device.
65779
6510
0
W
Specify different mirror IDs in
the mirror 1 and the mirror 2
parameters.
The same mirror ID is
specified in the mirror 1 and
the mirror 2 parameters.
65780
6510
5
W
The microprogram versions
between the DKCMAIN and
the SVP might not match.
Verify each microprogram
version.
The current microprogram
version of DKCMAIN does
not support creating a pair
by selecting primary or
secondary data volume.
65805
6510
Remote Web Console Error Codes 329