Table 54 Error Codes — Part Code 6505
(continued)
Failure
Level
Severity
Level
Recommended Action
Error Message
Error
Number
Part
Code
4
W
Check whether the primary
data volume is in any of the
following conditions:
•
Data in the primary data
volume is being copied;
correction copy or drive
copy is in progress.
•
The primary data volume
is in correction access
condition.
•
The primary data volume
is blocked.
•
The primary data volume
is being maintained.
•
The access attribute of the
primary data volume is
Read Only.
The specified primary data
volume cannot be used.
8744
6505
4
i
Check whether the secondary
data volume in the remote
storage system, which is
connected from hosts or the
SVP, is in any of the
following conditions:
•
The secondary data
volume is being used by
Dual Copy.
•
The secondary data
volume is being used by
Compatible XRC.
•
The secondary data
volume is being used by
PPRC or XP Continuous
Access.
•
The secondary data
volume is being used by
Concurrent Copy.
•
The access attribute of the
secondary data volume is
Read Only.
The secondary data volume
is already in use by another
system.
8745
6505
4
i
See the Installation and Open
Platform sections in the
maintenance manual to check
if the device emulation of the
primary data volume is
supported.
The emulation type of the
primary data volume is not
supported by XP Continuous
Access Journal or Universal
Replicator for Mainframe.
8746
6505
4
i
Check if the secondary data
volume is online. If the
secondary data volume is
online, vary the volume
offline, and then retry the
operation. If the secondary
data volume is connected to
a VM system, vary the volume
offline from the VM system.
The specified secondary data
volume is online.
8749
6505
270 Remote Web Console for Storage System Messages and Error Codes